EXPOSED FASTENER DETAILS

NO INSULATION

Click on the blue dots on the map to scroll down to the descriptions below to get a close up of each area shown on the map. Or, download the entire package details right here:

A - Horizontal Joint

Section at horizontal joint at EF Series exposed fastener panel system.
Application for insulation interior of sheathing (No external insulation).

B - Vertical Joint

Plan section at vertical joint at NorthClad® EF Series panel system. Application for insulation interior of sheathing (No external insulation).

C - Vertical Fastener

Plan section at typical vertical (field) fastener at EF exposed fastener rainscreen system. Application for insulation interior of sheathing (No external insulation).

D - Base Detail

Typical base detail at EF Exposed fastener panels. Application for insulation interior of sheathing (No external insulation).

E - Coping

Typical coping at NorthClad® EF Series. Application for insulation interior of sheathing (No external insulation).

G - Outside Corner

Typical outside corner flashing at exposed fastener panels. Application for insulation interior of sheathing (No external insulation).

H - Inside Corner

Showing inside corner flashing condition at exposed fastener rainscreen system. Application for insulation interior of sheathing (No external insulation).

J - Window Head

Section cut through window head showing flashing condition at EF Series exposed fastener cladding system. Application for insulation interior of sheathing (No external insulation).

K - Louver Head

Section at typical louver head flashing at EF Series rainscreen. Application for insulation interior of sheathing (No external insulation).

M - Door Head

Section through typical door head condition showing flashing at EF Series cladding. Application for insulation interior of sheathing (No external insulation).

R - Window Jamb

Plan section at window jamb showing EF Series flashing condition. Application for insulation interior of sheathing (No external insulation).

S - Louver Jamb

Plan section at louver jamb showing flashing condition at NorthClad® EF panels. Application for insulation interior of sheathing (No external insulation).

T - Door Jamb

Plan section through door jamb showing EF panel termination and flashing. Application for insulation interior of sheathing (No external insulation).

U - Window Sill

Section cut through window sill showing flashing condition at EF Series panels. Application for insulation interior of sheathing (No external insulation).

V - Louver Sill

Section cut through louver sill showing EF Series panel flashing. Application for insulation interior of sheathing (No external insulation).

L - Wall Panel To Soffit

Plan section showing EF Series panels at wall panel to soffit. Application for insulation interior of sheathing (No external insulation).

Z - Soffit to Wall Panel

Plan section showing EF Series soffit to wall panel transition. Application for insulation interior of sheathing (No external insulation).