Section 074213
Aluminum Floating Edge Wall Panels .125 plate
PART 1 GENERAL
1.1 SUMMARY
A. Section Includes:
1. Aluminum wall panel dry joint, pressure-equalized rainscreen system.
2. Accessories including sub girts, aluminum panel splines, aluminum panel bases, head
flashings, clips, shims, fasteners, and aluminum trim prefinished to match aluminum wall panels.
B. Related Sections:
Section 05 40 00 –
Section 06 10 00 –
Section 06 16 43 –
Section 07 25 00 –
Section 07 62 00 –
Section 07 92 00 –
Cold-Formed Metal Framing Rough Carpentry
Gypsum Sheathing
Air Barriers
Sheet Metal Flashing and Trim Joint Sealants
1.2 REFERENCES
A. Reference Standards:
Current edition at date of Bid.
B. American Architectural Manufacturers Association (AAMA):
AAMA 501.1
AAMA 508-07
C. ASTM International:
ASTM B 117
ASTM B 209
Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure
Voluntary Test Method and Specifications for Pressure Equalized Rain Screen Wall Cladding Systems
Standard Practice for Operating Salt Spray (Fog) Apparatus Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
Method of Tumbler Test for Coke
Method of Evaluating Degree of Chalking of Exterior Paints
Standard Test Methods for Abrasion Resistance of Organic Coatings by Falling Abrasive
Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates Practice for Testing Water Resistance of Coatings in 100% Relative Humidity
Standard Test Method for Strontium Ion in Brackish Water, Seawater, and Brines
Standard Test Method for Surface Burning Characteristics of Building Materials
Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
ASTM D 294
ASTM D 659
ASTM D 968
ASTM D 2244
ASTM D 2247
ASTM D 3352
ASTM E 84
ASTM E 283
ASTM E 330
ASTM E 331
– Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference
– Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference